this post was submitted on 20 Oct 2023
272 points (98.9% liked)

Electric Vehicles

3229 readers
119 users here now

A community for the sharing of links, news, and discussion related to Electric Vehicles.

Rules

  1. No bigotry - including racism, sexism, ableism, casteism, speciesism, homophobia, transphobia, or xenophobia.
  2. Be respectful, especially when disagreeing. Everyone should feel welcome here.
  3. No self-promotion
  4. No irrelevant content. All posts must be relevant and related to plug-in electric vehicles — BEVs or PHEVs.
  5. No trolling
  6. Policy, not politics. Submissions and comments about effective policymaking are allowed and encouraged in the community, however conversations and submissions about parties, politicians, and those devolving into general tribalism will be removed.

founded 1 year ago
MODERATORS
you are viewing a single comment's thread
view the rest of the comments
[–] [email protected] 47 points 1 year ago (2 children)

How do you fuck up your battery design by under-specing high voltage connections in an EV of all things?

JFC, Ford, can you try to sabotage the EV conversion more?

[–] [email protected] 34 points 1 year ago (1 children)

"Well you see, making those conductors undersized saved us $1 per unit, which allowed us to get the lower bid, and increase shareholder value at the time. Now, of course, is a different financial quarter and what we did before doesn't matter."

[–] [email protected] 11 points 1 year ago (1 children)

I guarantee there's a spreadsheet at Ford that does the math on whether saving that $1 per unit is worth it considering the chance of a recall. Looks like their gamble didn't pay off.

[–] [email protected] 1 points 1 year ago

One step closer to fight club.

[–] [email protected] 1 points 1 year ago

The battery is fine, problem is the isolation contactors in the HV electricity distribution junction box. Contactors overheat, most likely melting their electromagnet windings. No more electromagnet pulling the contactor closed, springs push it open, isolating the battery as designed for a fail safe condition, no more power. Though the fail conditions are supposed to be "control system is not happy, cuts pilot voltage to contactors". Instead of the contactor itself being the failing part.

But hey still, atleast it's not welding the contactor closed, that would be way worse.