People who joke about legos haven't stepped on this bad boy

you are viewing a single comment's thread
view the rest of the comments
[–] 10 points 9 months ago (14 children)

Is it normal for there to be no cord attached to these? That would stop them from facing this way on the floor

  • source
  • hideshow 14 child comments
  • [–] 14 points 9 months ago* (12 children)

    No, the cable comes out perpendicular to the pins (ie parallel to the wall).
    Which pretty much guarantees foot-pain orientation

  • source
  • parent
  • hideshow 12 child comments
  • [–] 6 points 9 months ago (10 children)

    Is this another safety factor, i.e. you can't easily rip appliances out by accident?

  • source
  • parent
  • hideshow 10 child comments
  • [–] 10 points 9 months ago* (6 children)

    It’s so the live wire disconnects first if you pull the cable out - it’s the shortest, then neutral, then ground. Whoever designed this really thought of everything.

  • source
  • parent
  • hideshow 6 child comments
  • [–] 4 points 9 months ago (2 children)

    Few things make me proud to be British, but the ingenious design of our plug sockets is one of them. TBF though we do need those safety features. Mains power here is 240v as opposed to 120v like a lot of countries. One mistake with a live wire would be the last one you'd ever make.

  • source
  • parent
  • hideshow 2 child comments
  • [–] 2 points 9 months ago (1 child)

    I doubt it.
    Tripping over a cable is as likely to damage the socket as it is to rip the cable out of the plug.
    Any appliance that increases risk by being unplugged should probably not be using a consumer connection...

    I think the 3 pin layout caused a lot of headaches, and the integrated fuse required a user-servicable plug.
    So it would have to be a split-shell design of some type, where the appliance cable would have to be cable-gripped to the same part as the plug/socket pins.
    Thus, a bottom-entry (heh) cable grip and a removable back plate that can only be unscrewed when it's unplugged.
    This was all in a time of bakelite. Plastic wasn't flexible.

    But no, I think tripping over an early bakelite g-type (I think it's officially a g-type) plug cable would likely shatter the plug and pull the pins out of the socket... If it didn't also damage the socket.

  • source
  • parent
  • hideshow 1 child comment
  • [–] 4 points 9 months ago

    The type G was designed when things were designed to do their jobs. Any pain inflicted by user error was considered a learning opportunity.

    The cord coming out the bottom means the plug can't pull out. Combined with the big, chunky plug and pins, means the cable will likely fail first if pulled. It will also fail at the live core first, leaving a safe plug in the wall.

    But yes, the foot pain is... impressive. It's just blunt enough to not generally penetrate the skin, but it can happen.

  • source
  • parent
  • [–] [S] 10 points 9 months ago*

    That's from a power brick that came with attachments for different regions.

    I've handled normal plugs as well and they tend to orient themselves prongs up too.

  • source
  • parent