this post was submitted on 24 Nov 2023
2 points (100.0% liked)
Home Networking
198 readers
1 users here now
A community to help people learn, install, set up or troubleshoot their home network equipment and solutions.
Rules
- Please stay on topic.
- Please use the search function to look for keywords related to what you want to ask before posting since most common issues have been answered.
- No Ads. This community is for support and discussion. Ads and self promotion are not welcome here.
- No product reviews or announcements. If you have a question about a product, be specific about what you want to know.
- Be civil. Don't be a jerk. Not being a jerk is surprisingly easy.
- No URL shorteners. URL shorteners tend to hide the real use of a link. For this reason, please use normal links, even if they're long.
- No affiliate links.
- No gatekeeping. With profession shall come professionalism. Extend help without judging others for their ignorance. The same goes for downvoting of comments or posts for "stupid questions" or not being as knowledgeable as others.
founded 1 year ago
MODERATORS
you are viewing a single comment's thread
view the rest of the comments
view the rest of the comments
I think you need a much better understanding of surge protection and lightning protection.
The first thing to look at is the passive protection. If you have a grounded metal structure anything within a 35 degree angle from the highest point is protected. It is slightly better, Google “rolling sphere” model. You need at least 2 ground rods and stranded grounding cables running to the ground rods. Do NOT share with the electrical ground and stay at least 10 feet away. Run fiber, NOT copper between buildings. If you can’t there are special surge arresters using PIN diodes or GDTs but it’s not ideal. Put one at each end.
That takes care of protecting against direct strikes. The rest is dealing with indirect strikes Put surge arresters on ALL attached lines…power or network. Keep in mind you get about 20 V of rise per inch away from the surge arrester so they really offer very little protection more than a few feet away. Standards test equipment against surges at a peak voltage equal to twice the nominal (marked) voltage plus 1,000 V
This also protects against switching surges that are far more common compared to lightning strikes.