this post was submitted on 24 Nov 2023
2 points (100.0% liked)
Home Networking
198 readers
1 users here now
A community to help people learn, install, set up or troubleshoot their home network equipment and solutions.
Rules
- Please stay on topic.
- Please use the search function to look for keywords related to what you want to ask before posting since most common issues have been answered.
- No Ads. This community is for support and discussion. Ads and self promotion are not welcome here.
- No product reviews or announcements. If you have a question about a product, be specific about what you want to know.
- Be civil. Don't be a jerk. Not being a jerk is surprisingly easy.
- No URL shorteners. URL shorteners tend to hide the real use of a link. For this reason, please use normal links, even if they're long.
- No affiliate links.
- No gatekeeping. With profession shall come professionalism. Extend help without judging others for their ignorance. The same goes for downvoting of comments or posts for "stupid questions" or not being as knowledgeable as others.
founded 1 year ago
MODERATORS
you are viewing a single comment's thread
view the rest of the comments
view the rest of the comments
You know that depending on the optical cable being used, grounding is still very much required, right? If this were my project and I was running underground cable to a barn, I’d use armored fiber cable to prevent rodent damage. Even if the cable is in conduit. Gophers and moles are the worst. I’ve had them chew through armored and loose tube fiber that was in conduit - which is why I will always go with the harder to destroy stuff.
There is a lot of conductive fiber optics cable, with armored being just one type. Hence the reason NEC § 770.100 requires conductive fiber optics cable be bonded. We know it’s not the fiber that is the problem - it’s the metal that is part of the cable’s construction that will conduct electricity.
The difference between running cat 6 and what you’re talking about is that armored fiber optic cable does not have to be electrically connected to the equipment at both ends. Ground loops and lightning propagation isn’t a problem with fiber, conductive or not.
Depending on your local building codes and whether they adopt the NEC for electrical safety, bonding some types of fiber is not an option, it’s required. For reference, see NEC § 770.100. Notice the use of the words “shall be bonded or grounded”.
The advice being given by some posters is to go with fiber like it is some way to get around bonding/grounding requirements. Thats not entirely true. Depending on the type of fiber, it must be bonded as fiber often has metallic tracer wire and armor that is part of its construction.
Because OP mentioned that it’s an underground run between a barn and a house, I would personally use armored cable. Rodents will eat through conduit and cable. I’ve replaced and repaired miles of feet of cable due to rodents - even armored cable in conduit. Rodents are persistent.