Not crazy, but the cool air from the crawlspace has to be replaced, probably by warmer air from outside. So you are cooling the attic but warming the crawlspace. Heat rises. What's the insulation between the crawlspace and house? You may be cooling the attic but warming the house. The attics I know are all vented to/from outside. I would be more inclined to put the cool air from the crawlspace into the house, rather than the attic.
post
Florida man makes risky post to Dull Men's Club.
You insulated the floor. you should insulate the roof if you want a cool attic. As others said, hot air might condense on cool walls of the crawlspace. I dont aerate my cellar in the summer for that reason.
Not crazy but that's your old vent stack for your poo pipe, so let's all pray that the scents soaked into that cast iron is long gone.
I've been working on venting my attic. It's a 1950s build with gable vents and a temperature-controlled fan. That made sense in the pre-ac days to push 130F attic air out, pull 80F house air through a popped attic door, and pull 90F air into the house (or 70+F night air in), I guess, but with retrofitted ac, it's not appropriate.
Nowadays, you want the attic to breathe and hopefully stay ambient. Luckily, the house came with a recent addition of a ridge vent. Unluckily, there's no soffit vents, so the air is still pretty stagnant. I don't use the fan because it's mostly pulling air from the gable vents near the ridge and pulling some from small gaps in the living space ceiling. If you pull from the living space, as others noted with your crawl space, the air must be replaced with outside air, so you have to determine if that's a benefit or a negative. I'm working on adding soffit vents to allow convection currents to flow and give the fan much more outside air availability (along with sealing ceiling openings). While my rafters sit over the wall top plates and provide a 5" gap between them to the soffit eaves , the last installation of batt insulation was rolled up and taped into the rafter bays - just like yours. That's an annoying thing to undo every 16" in hot, dusty, mildewy, rodent-contaminated conditions. I've compromised by cutting the soffit vent openings and poking the insulation with a rod from outside the house. I've wedged some foam rafter baffles in the bays to make sure they stay open, even though they're really meant for blown-in insulation rather than batts. I've used the 16" rectangular individual soffit vents so far, but I'm starting to think I can tackle replacing the soffit panels with vented panels myself while tackling some rotting trim at the same time.
I live where it snows in winter and while this will make the attic cooler, it's supposedly still a benefit to help reduce humidity and circulate air to reduce mustiness. What I know for sure is my gas heat can keep up, my electric ac cannot.
My version of your powered vent is, with a full/sealed basement, I've propped the door with a fan to blow basement air into the living space and hopefully exchange air downwards. That's a relatively close loop, if it worked at all, by exchanging air between two air groups already in near contact via the floor. Agreeing with others, I don't think it should be used for the attic air. But your setup could be a good start to test the effectiveness of the fan and to be a step towards a better solution.
Good luck. Stay cool. Building standards have changed a lot in the last 100 years. I can't wait to find out what common practice today gets ridiculed in 50 years. My bet is on spray-in wall insulation.
I have not studied them enough but my soffits could really use improved venting too. This will probably be my next step. I think poor circulation is why my attic gets so hot. My roof will need replacing in a year or two, I may replace my insulation with spray foam then.
I'm gathering data about the temperature difference in the attic now vs before my crazy pipe vent. I'll post it when I've got a couple of weeks worth.
The roofers may be able to do the vents for a small up charge. I wanted the gutter people to do mine but the gutter price alone was well beyond what my inexperienced DIY ass wanted to pay. I'd recommend adding a ridge vent with the roof though, as that's a very related task.
When I did one corner of the house with soffit vents, I couldn't feel anything in the attic, but I could see cobwebs dancing in the draft above the vents. Nothing in the other corners. So I have to trust they work. I started on the side with the most frequent breeze
People do this .... https://youtu.be/26F7X5rjtlM
But this is because many US houses don't have properly insulated and vented attics and roofs. Then people do things like paint their roofs silver.
Sounds good to me as long as the cast iron truly isn't connected to anything. If it's still an active plumbing vent you're fanning sewer gas into your attic. Also it would be a good idea to cap what's left of the pipe where it comes out of the roof so rain doesn't come in.