I've seen so many 10" servers that look amazing from the front and very polished, but then having a rats nest of cables and a mess at the back.

After 62 iterations and many 3D prints, blood, sweat, profanity and tears. I my design and implementation is finally done. image
I used Hexagons where possible, because as you know, Hexagons are the bestagons

This is Before:
image

And the After:
image
The ducky adds 200MHz

The front of my mini-rack is actually still somewhat of a mess, I thought I'd focus on the back first.

I've published it in excruciating detail on my GitHub Leave a Star if you like what you see.

I self host a bunch of stuff on here to get away from Big-Tech, and because I find it fun. For a lot more details see https://erasmus.works/

It always bothered me the the fronts of racs are modular, but not the backs, this solves that
If you have any questions feel free to ask, hopefully this helps other clear up their rats nests.

you are viewing a single comment's thread
view the rest of the comments
[–] 20 points 11 hours ago (3 children)

How is the power wired exactly? It looks like youve piggy backed off each cable before it, meaning the first cable is carrying the load from all after it which it usually isnt designed to do, should be fine if appropriately rated to the equipment.

Looks mint!

  • source
  • hideshow 3 child comments
  • [–] [S] 26 points 11 hours ago* (last edited 11 hours ago) (2 children)

    Yea each one runs through the previous module, so all the power goes through the first module.

    IEC 13/14 connectors are rated for 10A (2300 W at 230 V) which isn't much lower than what you can run through your wall outlet. And in reality they can probably handle 15A(What your wall can handle) as they are commonly refereed to as "Kettle cords" and used by kettles which draw ~13 Amps.

    That's very high, to give you an idea the 6 things I have plugged in draws ~240w, so I could chain up ~60 mini PC's and only then would I be over the ~2300w limit.

    I do now mention this in the Safety section of my "How to build this" write up

  • source
  • parent
  • hideshow 2 child comments
  • [–] 8 points 10 hours ago (1 child)

    Looks like youve done your research!

    Depending on the kettle model, most draw just under 10A these days. General household outlets (at least in australia) are only rated for 10A anyway.

    Ive used hundreds of kettle leads in my time and never seen one used for an actual kettle funnily enough

  • source
  • parent
  • hideshow 1 child comment